Högskolan i Skövde

his.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Sepsis and circulating miRNA: The road towards absolute quantification of unknown miRNA levels in plasma utilizing two-tailed RT-qPCR, while testing two extraction methods, striving to create multi-marker panel for sepsis diagnosis
Högskolan i Skövde, Institutionen för biovetenskap.
2021 (Engelska)Självständigt arbete på avancerad nivå (magisterexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [sv]

Sepsis is a preventable yet life threatening condition, resulting from body response to infection. Time is crucial in sepsis diagnosis since deterioration in patients’ health can occur rapidly. Blood culturing is the gold standard for diagnosis, along with clinical assessment. The discovery of miRNA in biofluids as a biomarker, founded the way for extensive research on its capabilities. MiRNA showed promises in diagnosing, assessing outcome and reporting sepsis progression. Since being delicate to handle while present in biofluid, the need was uttermost to find an effective way for miRNA isolation and detection, to facilitate developing multi-marker panel that help diagnosing sepsis, more efficiently than blood culturing. The current study aimed at using manual and robotic (QIAcube) methods, with MiRNeasy Serum/Plasma Advanced (Qiagen) as kit and protocol, to extract miRNA from human plasma samples. Plasma was either spiked with synthetic miR-223 to act as a positive control, or non-spiked. Once extraction was done, quality-quantity assessment was conducted using Qubit and Nanodrop. Two-tailed RT-qPCR (TATAA Biocenter) was used for miRNA quantification. QIAcube showed better results in quantity, hands-on and turn-around time compared to manual extraction, while better purity was scored for the manual method. While amplification appeared in all spiked samples, absolute quantification detected miRNA in some of the non-spiked samples. The study verified using the extraction kit with 100 μl of plasma is effective for miRNA extraction. Although faced with difficulties, absolute quantification using two-tailed RT-qPCR demonstrates its success in detecting lowly expressed miRNA. Future studies are needed for more optimized verification.

Ort, förlag, år, upplaga, sidor
2021. , s. 63
Nationell ämneskategori
Medicinsk biovetenskap
Identifikatorer
URN: urn:nbn:se:his:diva-20235OAI: oai:DiVA.org:his-20235DiVA, id: diva2:1579628
Ämne / kurs
Biovetenskap
Utbildningsprogram
Infektionsbiologi - magisterprogram
Handledare
Examinatorer
Tillgänglig från: 2021-07-09 Skapad: 2021-07-09 Senast uppdaterad: 2025-09-29Bibliografiskt granskad

Open Access i DiVA

fulltext(1773 kB)333 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1773 kBChecksumma SHA-512
13aafa938fb5f835ef391a99176f2bc265861fbdde11ca02e63015cc0b4e6d470f31d538c67f689e0dc97918ab8272c6673c179156b483af58311a30ea1398a5
Typ fulltextMimetyp application/pdf

Av organisationen
Institutionen för biovetenskap
Medicinsk biovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 334 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 860 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf