Högskolan i Skövde

his.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Sepsis and circulating miRNA: The road towards absolute quantification of unknown miRNA levels in plasma utilizing two-tailed RT-qPCR, while testing two extraction methods, striving to create multi-marker panel for sepsis diagnosis
Högskolan i Skövde, Institutionen för biovetenskap.
2021 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 20 poäng / 30 hpOppgave
Abstract [sv]

Sepsis is a preventable yet life threatening condition, resulting from body response to infection. Time is crucial in sepsis diagnosis since deterioration in patients’ health can occur rapidly. Blood culturing is the gold standard for diagnosis, along with clinical assessment. The discovery of miRNA in biofluids as a biomarker, founded the way for extensive research on its capabilities. MiRNA showed promises in diagnosing, assessing outcome and reporting sepsis progression. Since being delicate to handle while present in biofluid, the need was uttermost to find an effective way for miRNA isolation and detection, to facilitate developing multi-marker panel that help diagnosing sepsis, more efficiently than blood culturing. The current study aimed at using manual and robotic (QIAcube) methods, with MiRNeasy Serum/Plasma Advanced (Qiagen) as kit and protocol, to extract miRNA from human plasma samples. Plasma was either spiked with synthetic miR-223 to act as a positive control, or non-spiked. Once extraction was done, quality-quantity assessment was conducted using Qubit and Nanodrop. Two-tailed RT-qPCR (TATAA Biocenter) was used for miRNA quantification. QIAcube showed better results in quantity, hands-on and turn-around time compared to manual extraction, while better purity was scored for the manual method. While amplification appeared in all spiked samples, absolute quantification detected miRNA in some of the non-spiked samples. The study verified using the extraction kit with 100 μl of plasma is effective for miRNA extraction. Although faced with difficulties, absolute quantification using two-tailed RT-qPCR demonstrates its success in detecting lowly expressed miRNA. Future studies are needed for more optimized verification.

sted, utgiver, år, opplag, sider
2021. , s. 63
HSV kategori
Identifikatorer
URN: urn:nbn:se:his:diva-20235OAI: oai:DiVA.org:his-20235DiVA, id: diva2:1579628
Fag / kurs
Bioscience
Utdanningsprogram
Infection Biology - Master’s Programme 60 ECTS
Veileder
Examiner
Tilgjengelig fra: 2021-07-09 Laget: 2021-07-09 Sist oppdatert: 2025-09-29bibliografisk kontrollert

Open Access i DiVA

fulltext(1773 kB)333 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1773 kBChecksum SHA-512
13aafa938fb5f835ef391a99176f2bc265861fbdde11ca02e63015cc0b4e6d470f31d538c67f689e0dc97918ab8272c6673c179156b483af58311a30ea1398a5
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 334 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 860 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf