Högskolan i Skövde

his.sePublikationer
Driftstörningar
Just nu har vi driftstörningar på sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Body composition in male elite athletes, comparison of bioelectrical impedance spectroscopy with dual energy X-ray absorptiometry
Institute of Neuroscience and Physiology, Sahlgren ska Academy, University of Gothenburg, Sweden.
Department of Clinical Nutrition, Sahlgrenska Academy, University of Gothenburg, Sweden.
Department of Clinical Nutrition, Sahlgrenska Academy, University of Gothenburg, Sweden.
Högskolan i Skövde, Institutionen för vård och natur.
2008 (Engelska)Ingår i: Journal of Negative Results in BioMedicine, E-ISSN 1477-5751, Vol. 7, nr 1, s. 1-5, artikel-id 1Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background

The aim of this study was to compare body composition results from bioelectrical spectroscopy (BIS) with results from dual energy X-ray absorptiometry (DXA) in a population of male elite athletes. Body composition was assessed using DXA (Lunar Prodigy, GE Lunar Corp., Madison, USA) and BIS (Hydra 4200, Xitron Technologies Inc, San Diego, California, USA) at the same occasion. Agreement between methods was assessed using paired t-tests and agreement-plots.

Results

Thirty-three male elite athletes (soccer and ice hockey) were included in the study. The results showed that BIS underestimates the proportion of fat mass by 4.6% points in the ice hockey players. In soccer players the BIS resulted in a lower mean fat mass by 1.1% points. Agreement between the methods at the individual level was highly variable.

Conclusion

Body composition results assessed by BIS in elite athletes should be interpreted with caution, especially in individual subjects. BIS may present values of fat mass that is either higher or lower than fat mass assessed by DXA, independent of true fat content of the individual.

Ort, förlag, år, upplaga, sidor
BioMed Central (BMC), 2008. Vol. 7, nr 1, s. 1-5, artikel-id 1
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:his:diva-2725DOI: 10.1186/1477-5751-7-1PubMedID: 18211680Scopus ID: 2-s2.0-40849135693OAI: oai:DiVA.org:his-2725DiVA, id: diva2:160045
Tillgänglig från: 2009-02-11 Skapad: 2009-02-11 Senast uppdaterad: 2024-02-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus
Av organisationen
Institutionen för vård och natur
I samma tidskrift
Journal of Negative Results in BioMedicine
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 92 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf