Högskolan i Skövde

his.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Hydrogen-assisted stress corrosion cracking of high strength steel
KTH, Materialvetenskap.ORCID-id: 0000-0003-2698-5445
2011 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgaveAlternativ tittel
Väte-inducerad spänningskorrosion på höghållfasta stål (svensk)
Abstract [en]

In this work, Slow Strain Rate Test (SSRT) testing, Light Optical Microscopy (LOM) and Scanning Electron Microscopy (SEM) were used to study the effect of microstructure, corrosive environments and cathodic polarisation on stress corrosion cracking (SCC) of two grades of high strength steels, Type A and Type B. Type A is manufactured by quench and tempered (Q&T) method. Type B, a normalize steel was used as reference. This study also supports electrochemical polarisation resistance method as an effective testing technique for measuring the uniform corrosion rate. SSRT samples were chosen from base metal, weld metal and Heat Affected Zone (HAZ). SSRT tests were performed at room temperature under Open Circuit Potential (OCP) and cathodic polarisation using 4 mA/cm2 in 1 wt% and 3.5 wt% NaCl solutions. From the obtained corrosion rate measurements performed in 1 wt% and 3.5 wt% NaCl solutions it was observed that increased chloride concentration and dissolved oxygen content enhanced the uniform corrosion for all tested materials. Moreover, the obtained results from SSRT tests demonstrate that both Q&T and normalized steels were not susceptible to SCC in certain strain rate (1×10-6 s-1) in 1 wt% and 3.5 wt% NaCl solutions under OCP condition. It was confirmed by a ductile fracture mode and high reduction in area. The weld metal of Type A with acicular ferrite (AF), pro-eutectoid (PF) and bainite microstructure showed higher susceptibility to hydrogen assisted stress corrosion cracking compared to base metal and HAZ. In addition, typical brittle intergranular cracking with small reduction in area was observed on the fracture surface of the Type A due to hydrogen charging.

sted, utgiver, år, opplag, sider
2011. , s. 65
Emneord [en]
Hydrogen assisted stress corrosion cracking, Hydrogen embrittlement, High strength steel, Slow Strain Rate Test
HSV kategori
Identifikatorer
URN: urn:nbn:se:his:diva-22016OAI: oai:DiVA.org:his-22016DiVA, id: diva2:1708236
Eksternt samarbeid
Swerea/KIMAB
Presentation
2011-08-24, Swerea KIMAB, Stockholm, 08:08 (engelsk)
Uppsök
Technology
Veileder
Examiner
Tilgjengelig fra: 2022-11-03 Laget: 2022-11-03 Sist oppdatert: 2022-11-03bibliografisk kontrollert

Open Access i DiVA

fulltekst(6493 kB)192 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 6493 kBChecksum SHA-512
8ee5d8d7c63230ff9000a3b5dde813d0da5b6361f45fa52ba2407e7bcdba150ab67a41da89cf2f6c5655f9793cbae3bf67c4baf3a3d1f55b82379fdb39bc3b37
Type fulltextMimetype application/pdf

Person

Ghasemi, Rohollah

Søk i DiVA

Av forfatter/redaktør
Ghasemi, Rohollah

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 192 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 63 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • apa-cv
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf